Single button control station:
Momentary type, control circuit 24V. A.C.
Solid state dual automatic closer “timer”:
Red and green warning lights (60 watts bulb maximum). If door is closed, push of button starts door up and turns green light on for a preset time. (Adjustable without tools from 5 seconds to 180 seconds). At the end of the preset time, the red lights is turned on for 5 seconds to 90 seconds (adjustable) and the door closes automatically. If button is pressed or any other control used to open door, while door is travelling downward, it will instantly reverse to open position and reset cycle of timer. If door is in the open position and button or any other control used to close door is activated, timer will automatically reset to preset timing.
Toggle switch:
Is provided to cut out timer when automatic closing is not desired, such as in summer.
Limit switches:
Screw type with oilite bronze cams and precision type micro switches for both up and down position. (Easily adjustable without tools within 1/2″ (1.25cm) of door travel).
Automatic instant reverse mechanism:
If downward travelling door meets an obstruction, it will instantly reverse and automatically stop at fully open position for your safety and protection. This built-in instant reverse, load-sensing device is easily accessible externally for adjustable without tools.
Reduction system:
V belt, roller chain, steel sprockets are used for efficient, long lasting, quiet operation, rotating on high speed ballbearings as well as self-lubricating, self-aligning pillow block bearings. Door speed approx. .8 to 1.0 ft. per second. (.24m to .3m per second)
Trolley assembly:
Heavy duty aluminium alloy travelling carriage slides on dual heavy angle tracks with full No. 41 push and pull roller chain drive.
Quick release lifting arm:
Will quickly disengage operator from door, without tools for manual operation, in the event of power failure.
Headroom required:
2″ (5cm) minimum from door’s highest arc of travel.
Backroom:
4’7″ (137.5cm) plus door height.
Optional at extra cost “special reverse mount”:
3’0″ (.9m) plus door height.
Motor:
1/3 H.P. (.33hp), 120V., 60 cycles, 1 phase instant reverse type of recognized manufacture, thermally protected with thermo overload switch.
Finish:
Primed with rust-proof primer and spray painted in blue hammer tone enamel.
Note:
These operators can be wired to receive radio and photo electric control systems, loop detectors, etc., for fully automatic door operation.
Accessories:
See auxiliary equipment for additional information.
Single Push Button Control:
Momentary contact type.
Dual-Function Timer – Plug Type:
Consumption 24V. A.C., power requirement maximum 2.3 watts, resistance tolerance adjustable +5% delta time +10%, temperature -40°C. Transient protection 100V. for 100M. sec., repetition capacity +3% maximum, polarity protection: yes. The arming consists of a bucket type power socket * holes, 10 amp. 300V. A.C. Terminal: Screw type.
Toggle Switch:
On-off, normally opens to disconnect the timer and keep the door open when desired, such as during the summer.
Step-down Transformer:
120V. A.C. primary to 24V. A.C. secondary, 25 V.A. minimum (24V control circuit for your protection).
Reduction:
Includes a No. 4L V-belt, two aluminum pulleys, one of 1-1/2″ (3.75cm) and one of 9″ (22.5cm), 41B9 and 41B23 sprockets with RC41 roller chain, mounted on a 5/8″ (2.05cm) cold-rolled steel shaft, rotating on 5/8″ (2.05cm) self-lubricating and self-aligning support bearings. Approximate door speed 12″/second (0.3m/second).
Chassis:
Angles of 2″ x 2″ x 1/8″ (5cm x 5cm x .31cm) reinforced with steel plates.
Carrier:
Angles of 2″ x 2″ x 1/8″ (5cm x 5cm x .31cm) mounted with a 3/8″ (9.5mm) rod and a center roller spreader bar to prevent the chain from rubbing.
Starter:
Eight-branch plug, general utility relay, bipolar, double action, 10 amp., coil capacity 24V. A.C., contactors 240V. A.C., resistivity 2000V. A.C. maximum, under transparent “P” type dust cover. Bucket type arming 8 holes, 10 amp., 300V. A.C.
Tolerance Contactors:
Screw type with two oilite bronze grooved cams, guided by a profiled galvanized steel plate, mounted on a threaded shaft of 5/8″ (2.05cm) cold-rolled NF steel, rotating on lubricated ball bearings. The cams operate two micro switches that cut off the current when the door is in the open or closed position. Tolerance contactor command force 4 oz. (113.4g) maximum, contact gap .020″ (.05cm), pre-travel .250″ (.625cm).
Instant Reversing Mechanism:
Spring detection device, including lever arm assembly, steel sprocket No. 41B9 and micro switch. The setting can be done from the outside by turning a wing screw to the right to decrease sensitivity.
Control Box:
14 gauge steel box, measuring 8″ x 10″ x 4-1/2″ (20cm x 25cm x 11.25cm) with removable cover for easy service and maintenance, mounted on the chassis using 4 galvanized steel bolts.
Motor:
1/3 H.P. (.33HP), 115V., 60 cycles, single phase, 1725 RPM permanently lubricated bearings instant reversal type. APD 6.2, CD. 1.0, thermal overload protection, rigid type 56 frame.
The unit is pre-connected at the factory with color-coded and labeled wiring. Diagrams are included with each operator. The device is operated and checked before shipment.
Leader in door and gate operator